M8 - M12 digital outputs modules Solenoid valves manifold Series 3000 1 1 | 547 AIR DISTRIBUTION Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice General - 8 M8 digital outputs module Module has 8 M8 female connectors. Outputs have PNP logic, 24VDC ± 10%. Maximum available current per output is 100mA. Electric power on outputs module is supplied by pin 4 of the M12 power connector on the network node or by the expansion module (5030.M12 part number). Power supply presence is displayed by “PWR OUT” green LED light-on. The module takes up 8 outputs (8 bits of the output bytes) of the serial node. Ordering code 5130.08.M8 General - 8 M12 digital outputs module Module has 4 M12 female connectors. Outputs have PNP logic, 24VDC ± 10%. Maximum available current per output is 100mA. Electric power on outputs module is supplied by pin 4 of the M12 power connector on the network node or by the expansion module (5030.M12 part number). Power supply presence is displayed by “PWR OUT” green LED light-on. The module takes up 8 outputs (8 bits of the output bytes) of the serial node. Ordering code 5130.08.M12 Scheme / Overall dimensions and I/O layout 42 90 28 Scheme / Overall dimensions and I/O layout 42 90 28 M8 3P female connector PIN DESCRIPTION 1 NC 3 GND 4 OUTPUT 4 3 1 M12 5P female connector PIN DESCRIPTION 1 NC 2 OUTPUT B 3 GND 4 OUTPUT A 5 NC M12A 5P FEMALE 3 2 4 5 1
RkJQdWJsaXNoZXIy NzYzOTY1