CATGEN-EN

Additional modules Solenoid valves manifold Series 3000 1 AIR DISTRIBUTION 1 | 552 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice General - Additional power supply module Ordering code 5030.M12 Additional power supply module 5030.M12 supplies additional electric power for downstream optional modules, where “downstream” means farther from serial node. Electric connection of the module to external power supply unit occurs via an M12 4 pins type A male connector. M12 connector has two different pins to power up inputs (pin 1) and outputs (pin 4). Presence of each power supply rail is indicated by corresponding green LED. Scheme / Overall dimensions and I/O layout M12 4P male connector PIN DESCRIPTION 1 + 24 VDC 2 NC 3 GND 4 PWR OUT M12A 4P MALE 3 2 4 1 Electric power supply provided by additional power supply module Electric power supply provided by serial system General - Optional position module Ordering code 5030.T00 Optional position module is employed to protect manifold connections where no module has yet been installed. Optional position modules must be installed at the left end of the system, that is downstream the other modules. Configuration example The code 5030.T00 can be replaced by any of the modules presented in the previous pages, as long as the availability of the necessary inputs or outputs is checked on the node.