Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Air service units Series Airplus 2 AIR TREATMENT 2 | 28 Characteristic curves 0 1 2 3 4 5 6 7 0 200 400 600 800 1000 1200 1400 1600 1800 Flow (Nl/min) Downstream pressure (bar) 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 10 Inlet pressure (bar) Flow Q=34 Nl/min Flow Q=22 Nl/min Flow Q=15 Nl/min Downstream pressure (bar) Flow rate curves Adjustment characteristic 0 500 1500 2000 2500 3000 1000 0 1 2 3 4 5 6 7 Flow (Nl/min) Downstream pressure (bar) 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 10 Flow Q=78 Nl/min Flow Q=50 Nl/min Flow Q=33 Nl/min Inlet pressure (bar) Downstream pressure (bar) 0 1 2 3 4 5 6 7 0 1000 2000 3000 4000 5000 Flow (Nl/min) Downstream pressure (bar) 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 10 Flow Q=138 Nl/min Flow Q=90 Nl/min Flow Q=60 Nl/min Inlet pressure (bar) Downstream pressure (bar) 0 2000 4000 6000 8000 10000 12000 0 1 2 3 4 5 6 7 Flow Q [dm3/min] (ANR) Downstream pressure (bar) Q=10% Qmax.= 1600 dm3/min (ANR) Q=2% Qmax.= 320 dm3/min (ANR) 1,5 2 2,5 3 0 1 2 3 4 5 6 7 8 9 10 Inlet pressure (bar) Downstream pressure (bar) Flow rate curves Adjustment characteristic Flow rate curves Adjustment characteristic Flow rate curves Adjustment characteristic Size 1 - G1/4” 0-8 bar P1=7 bar Size 2 - G3/8” 0-8 bar P1=7 bar Size 3 - G1/2” 0-8 bar P1=7 bar Size 4 - G1” 0-8 bar P1=10 bar
RkJQdWJsaXNoZXIy NzYzOTY1