CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Air service units Series Airplus 2 AIR TREATMENT 2 | 46 Characteristic curves 0 1 2 3 4 5 6 7 0 50 100 150 200 250 300 350 400 450 500 Flow (Nl/min) Dowstream pressure (bar) 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 10 Inlet pressure (bar) Flow Q=34 Nl/min Flow Q=22 Nl/min Flow Q=15 Nl/min Downstream pressure (bar) Flow rate curves Adjustment characteristic Size 1 - G1/4” 0-8 bar P1=7 bar Order codes Version N : Technopolymer body and metal inserts T : Technopolymer body and thread Size and connections 1A : Size 1 - G1/8” 1B : Size 1 - G1/4” 1C : Size 1 - 1/4” NPT only for N version Pressure measurement options B : G1/8” - 1/8” NPT thread M : Integrated pressure gauge Pressure range A : 0 - 2 bar B : 0 - 4 bar C : 0 - 8 bar D : 0 - 12 bar Relieving options : With relieving F : Controlled refiel and improved relieving L : Without relieving R : Improved relieving Knob options : Non-lockable version K : Lockable version U : Lockable version with universal key Example : T171BBD : Size 1 pressure regulator for manifold G1/4”, 0 - 12 bar T 17 1B B D