CATGEN-EN

Air service units Series 1700 2 AIR TREATMENT 2 | 112 Overall dimensions and technical information are provided solely for informative purpose and may be modified without notice. Technical characteristics Size Size 1 Size 3 Body and connections type Aluminium body, integrated aluminium connections IN / OUT connections G1/4” G1/2” Assembly configuration Stand alone Panel mounting With fixing bracket Stand alone Panel mounting With fixing bracket Assembly position Indifferent Fluid 20μ filtered air and preferably non lubricated Air flow with inlet pressure 10 bar (NI/min) 5 Pressure range (bar) 0,1 - 2 / 0,1 - 4 / 0,1 - 7 / 0,1 - 10 Regulation Manual push and lock with pressure Manual lockable with accessories Pressure measurement G1/8” Pressure gauge connection port Max. fittings torque IN / OUT connections G1/4” metal: 20 G1/2” metal: 30 Operational characteristics Size Size 1 Size 3 Maximum working pressure (bar) 10 Minimum working pressure (bar) 0,5 Working temperature (°C) -5 ÷ +50 Weights Size Size 1 Size 3 Aluminium body version (g) 380 970 Accurate capacity to maintain set pressure Sensitivity combined with high relieving rates High flow rate with extremely low pressure drop Pressure adjusting lockable handle by simply pressing it donwards in the desired position Aluminium body Ring nut for panel mounting Construction with controlled refiel Atex certification (II 2GD) on request High sensitive air pressure regulators with high flow rate relieving

RkJQdWJsaXNoZXIy NzYzOTY1