CATGEN-EN

Air service units Series 1700 2 AIR TREATMENT 2 | 146 Overall dimensions and technical information are provided solely for informative purpose and may be modified without notice. Technical characteristics Size Size 1 Size 2 Size 3 Size 4 Body and connections type Aluminium body IN / OUT Connections G1/8” G3/8” G1/2” Ø36 Assembly configuration Stand alone Stand alone Stand alone Stand alone Assembly position Indifferent Microswitch capacity (A) 1 Microswitch Maximum voltage (VAC) 250 Grade of protection IP65 (with connector assembled) Operational characteristics Size Size 1 Size 2 Size 3 Size 4 Maximum working pressure (bar) 13 Working temperature (°C) -5 ÷ +50 Pressure range (bar) 2÷10 Weights Size Size 1 Size 2 Size 3 Size 4 Aluminium body version (g) 160 200 220 450 The pressure switch can be set at desired pressure from 2 to 10 bar with electrical connection applied The electrical connection is made by mean of a 15 mm connector DIN 43650 type C The microswitch contact could be Normally Closed or open (change over switch) Order codes 17 Type 14A : Pressure switch adapter (only for size 1) 14B : Pressure switch (for all sizes) 14C : Pressure switch complete with adapter (only for size 1) 24A : Pressure switch adapter (only for size 2) 24C : Pressure switch complete with adapter (only for size 2) 34A : Pressure switch adapter (only for size 3) 34C : Pressure switch complete with adapter (only for size 3) 44A : Pressure switch adapter (only for size 4) 44C : Pressure switch complete with adapter (only for size 4) 34C Example: 1734C Pressure switch adapter size 3 Pressure Switch complete with adapter

RkJQdWJsaXNoZXIy NzYzOTY1