Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 3 | 203 Rodless cylinders Series 1605 -Fixing devices 3 Pneumatic actuation Instruction on how to use the sensors properly Particular attention must be paid not to exceed the working limits listed in the tables and that the sensor is never connected to the mains without a load connected in series; these are the only measures that if not observed can put the circuits out of order. In the case of direct current ( D.C.) connection polarities must be respected, that is the brown wire to the positive load (+) and the blue to the negative (-). If these are inverted the sensor remains switched, the load connected and the led turned off. However, this would not damage the circuit. For the "U" type sensors attention must be paid that the length of the cable doesn't exceed 8 metres, with tension above 100 V. In this case a serial resistance is added to reduce the cumulative effects of the line. As an example 1000 W per 100-130 V e 2000 W per 200-240 V. Bore AN AZ L LB 1600.A 1600.B 25 12,5 15 55 45 3 1 32 20 15 68 58 3 1 50 32,5 15 94 84 3 1 40 25 15 79 69 3 1 63 40 15 110 100 3 1 Weight g 1600.B 1600.A AN AZ L AN AZ LB Sensor brackets codes 1580._, MRS._, MHS._ ► Ordering code ►Sensor brackets codes 1600._, SRS._, SHS._ Ordering code Sensors For technical characteristics and ordering codes see magnetic sensors section ►