Solenoid valves for fluids - F300 Series FLUID CONTROL Overall dimensions and information are provided solely for informative purposes and may be modified without notice. 3 Resistance to fluids The table below serves to general information relating to the compatibility between FPM (fluorocarbon) and a number of neutral fluids. Where there are corrosive fluids, in order to establish compatibility, it is important to be aware of all the data relating to use: temperature, concentration and composition of the fluid. Fluid Ethyl acetate Non Compatible Acetylene Compatible Vinegar Non Compatible Acetone Non Compatible Calcareous water Compatible Hot water <75°C Compatible Hot water and steam <140°C Non Compatible Water with glycol Compatible Deionised water Compatible Demineralised water Compatible Hydrogen peroxide Compatible Soapy water Compatible Carbon dioxide (liquid) Non Compatible Dry carbon dioxide (gas) Compatible Argon Compatible Nitrogen Compatible Petrol/Gasoline Compatible Benzol Non Compatible Butane Compatible Chloroform Non Compatible Ethyl Chloride Compatible Methyl chloride Non Compatible Helium Compatible Heptane Compatible Hexane Compatible Ethane Compatible Ethanol Non Compatible Formaldehyde Compatible Freon Non Compatible Natural gas Compatible Diesel oil Compatible Glycerine Compatible Ethylene glycol Compatible Hydrogen Compatible Isobutane Compatible Isopentane Compatible Methane Compatible Methanol Non Compatible Calcium monoxide Compatible Neon Compatible Nitrobenzene Non Compatible Mineral oil Compatible Oxygen Compatible Pentane-n Compatible Propanol-n Compatible Propane-n Compatible Carbon sulphide Non Compatible Toluene Compatible Dry trichloroethylene Compatible Xylene Compatible