NW96-EN
Solenoid valves manifold Series 3000 - MANIFOLD - Version 3400 (15,5mm) - Module assembly instructions 37 Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice AIR DISTRIBUTION 5. Fix the offset compensation plate 3400.P0 to the last single module 1. Fix the dedicated adapter (code 3100.KA.00) to the manifold. 2. Assemble the required modules. 4. To lock: rotate anticlockwise (in the direction of the LOCK print on the case). To unlock: rotate clockwise (in the direction of the UNLOCK print on the case). The same procedure shall be used to add or remove any module. 3. Complete the assembly with the 3100.KT.00 end plate kit.
Made with FlippingBook