NW96-EN

PROFIBUS DP protocol nodes 39 Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice AIR DISTRIBUTION Solenoid valves manifold Series 3000 - Serial systems General - PROFIBUS DP protocol nodes Technical characteristics PROFIBUS DP nodes handle up to 64 inputs and outputs, both divided into 8 bytes. Output typologies include solenoid valves, digital outputs (e.g. 5130.08.M8) and analogue outputs (e.g. 5130.2T.00). Connectable inputs typologies include digital inputs modules (e.g. 5230.08.M8), analogue inputs modules (e.g. 5230.2T.00), and Pt100 inputs modules (e.g. 5230.4P.02). Optional modules can be connected to the manifold in any order and configuration. Electrical power must be supplied via circular M12 4 pins type A male connector. The separation between 24VDC supply of the node and 24VDC of the outputs allows to turn off outputs leaving the node and eventual inputs operational. PROFIBUS DP network connection is achieved via two circular male-female M12 5 pins type B connectors, connected in parallel; connector pinout is PROFIBUS Interconnection Technology compliant (Version 1.1 August 2001). Network node address is set via DIP-switch. Internal termination resistance is on-board and can be enabled via DIP-switch as well. PROFIBUS DP node versions differ by number of outputs directly allocated to solenoid valve positions. 5330.64.32PB part number provides the first 32 out of 64 outputs, corresponding to less significant 4 bytes, are permanently allocated to solenoid valve positions, regardless how many they physically are and how many valves are installed. The remaining 32 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. 5330.64.48PB part number provides the first 48 out of 64 outputs, corresponding to less significant 6 bytes, are permanently allocated to solenoid valve positions, regardless how many they physically are and how many valves are installed. The remaining 16 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. Two part-numbers have been provided to tailor configuration on your needs. 5330.64.48PB part number is recommended in case several solenoid valves must be handled, whilst ensuring room for future expansions. 5330.64.32PB part number is recommended in case increased flexibility is needed for digital outputs. To better understand different possibilities offered, some configuration examples are made in the following pages. Ordering code 5330.64.32PB 5330.64.48PB Scheme / Overall dimensions and I/O layout 42 90 NETWORK connectors PIN SIGNAL DESCRIPTION 1 VP Optional Power supply plus, (P5V) 2 A-line Receive / Transmit data -N, A-line 3 DGND Data Ground (reference potential to VP) 4 B-line Receive / Transmit data -P, B-line 5 SHIELD Shield or PE POWER SUPPLY connector PIN DESCRIPTION 1 + 24 VDC (NODE & INPUTS) 2 N.C. 3 GND 4 +24 VDC (OUTPUTS) M12A 4P MALE 4 1 3 2 28 M12B 5P FEMALE 3 2 4 5 1 4 1 3 2 M12B 5P MALE 5 Specifications PROFIBUS DP Case Reinforced technopolymer Power supply Power supply connection M12 4 P male connector type A (IEC 60947-5-2) Power supply voltage +24 VDC ±10% Node consumption (without inputs) 50 mA Power supply diagnosis Green LED PWR / Green LED OUT Network Network connectors 2 M12 5 P connectors male-female type B Baud rate 9,6 - 19,2 - 93,75 - 187,5 - 500 - 1500 - 3000 - 6000 - 12000 Kbit/s Addresses possible numbers From 1 to 99 Max. node in net 100 (slave + master) Bus maximum recommended length 100 m at 12 Mbit/s - 1200 m at 9,6 Kbit/s Bus diagnosis Green LED + red LED Configuration file Available from our web site http://www.pneumaxspa.com IP Rating IP65 when assembled Temperature range 0°C ... +50°C

RkJQdWJsaXNoZXIy NzYzOTY1