NW96-EN
EtherNet/IP / EtherCAT ® / PROFINET IO RT protocol nodes 40 Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice AIR DISTRIBUTION Solenoid valves manifold Series 3000 - Serial systems General - EtherNet/IP / EtherCAT ® / PROFINET IO RT protocol nodes Case Reinforced technopolymer Power supply Power supply connection M12 4 P male connector type A (IEC 60947-5-2) Power supply voltage +24 VDC ±10% Node consumption (without inputs) 100 mA Power supply diagnosis Green LED PWR / Green LED OUT Network Network connectors 2 M12 4 P female connectors type D (IEC 61076-2-101) Baud rate 100 Mbit/s Maximum distance between 2 nodes 100 m Bus diagnosis 2 bicolor red / green LEDs + protocol LEDs Configuration file Available from our web site http://www.pneumaxspa.com IP Rating IP65 when assembled Temperature range 0°C ... +50°C Technical characteristics 5730.128.48PN, 5730.128.48EC and 5730.128.48EI nodes handle up to 128 inputs and outputs, both divided into 16 bytes. Output typologies include solenoid valves, digital outputs (e.g. 5130.08.M8) and analogue outputs (e.g. 5130.2T.00). Connectable input types include digital inputs modules (e.g. 5230.08.M8), analogue inputs modules (e.g. 5230.2T.00) and Pt100 inputs modules (e.g. 5230.4P.02). Optional modules can be connected to the manifold in any order and configuration. Electric power must be supplied via circular M12 4 pins male type A connector. The separation between 24VDC supply of the node and 24VDC of the outputs allows to turn off outputs leaving the node and eventual inputs operational. The network connection is achieved via two circular female connectors (M12 4 pins, type D); these two circular connectors belong to two separate communication ports. In 5730.128.48PN, 5730.128.48EC and 5730.128.48EI part numbers the first 48 out of 128 outputs, corresponding to less significant 6 bytes, are permanently allocated to the solenoid valve positions, regardless how many they are and how many valves are installed. The remaining 80 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. When more than 64 inputs are needed and current coming from 24VDC rail is higher than 2.5A, the use of additional power supply module (part number 5030.M12) is mandatory. 5030.M12 additional power supply module must be plugged-in upstream to the modules exceeding the above stated current limit, therefore close to the network node. On the other hand, whenever 64 outputs are used and further optional outputs modules are required, if total computed simultaneous current is higher than 2A, the 5030.M12 additional power supply module is mandatory. 5030.M12 additional power supply module is plugged-in upstream to additional modules; it will supply electrical power to downstream modules. If 5030.M12 additional power supply module has been already integrated to supply inputs modules, it is not necessary to install a second one, since it already supplies outputs modules. Ordering code 5730.128.48EI 5730.128.48EC 5730.128.48PN Scheme / Overall dimensions and I/O layout 42 90 PIN SIGNAL DESCRIPTION 1 TX + Ethernet Transmit High 2 RX + Ethernet Receive High 3 TX - Ethernet Transmit Low 4 RX - Ethernet Receive Low POWER SUPPLY connector PIN DESCRIPTION 1 + 24 VDC (NODE & INPUTS) 2 N.C. 3 GND 4 +24 VDC (OUTPUTS) M12A 4P MALE 4 1 3 2 28 NETWORK connectors 3 2 4 1 M12D 4P FEMALE 3 2 4 1 M12D 4P FEMALE
Made with FlippingBook
RkJQdWJsaXNoZXIy NzYzOTY1