NW96-EN

IO-Link protocol interfaces 41 Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice AIR DISTRIBUTION Solenoid valves manifold Series 3000 - Serial systems General - IO-Link protocol interfaces Specifications IO-Link Specification v1.1 Case Reinforced technopolymer Outputs PNP equivalent outputs +24 VDC ±10% Maximum output number 64 Maximum output simultaneously actuated 64 Network Network connectors Class B port Communication speed COM2 (38.4 kbaud) Maximum distance from Master 20 m Bus diagnosis 1 green and 1 red LED for status Vendor ID / Device ID 1257 (hex 0x04E9) / 3000 (hex 0x0BB8) Configurations file IODD Available from our web site http://www.pneumaxspa.com IP Rating IP65 when assembled Temperature range 0°C ... +50°C IO-Link interfaces handle up to 64 inputs and outputs, both divided into 8 bytes. Output typologies include solenoid valves, digital outputs (e.g. 5130.08.M8) and analogue outputs (e.g. 5130.2T.00). Connectable inputs typologies include digital inputs modules (e.g. 5230.08.M8), analogue inputs modules (e.g. 5230.2T.00), and Pt100 inputs modules (e.g. 5230.4P.02). Optional modules can be connected to the manifold in any order and configuration. Electrical power and connection to IO-Link Master come through male circular connector M12, 5 poles, type A, “CLASS B” according to IO-Link specifications. L+/L- electrical power allows to supply the interface while P24/N24 electrical power allows to supply inputs and outputs modules, including solenoid valves, connected to the manifold. L+/L- and P24/N24 power supplies are galvanically isolated into the IO-Link interfaces. IO-Link interface versions differ by number of outputs directly allocated to solenoid valve positions. 5830.64.32IK part number provides the first 32 out of 64 outputs, corresponding to less significant 4 bytes, are permanently allocated to solenoid valve positions, regardless how many they physically are and how many valves are installed. The remaining 32 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. 5830.64.48IK part number provides the first 48 out of 64 outputs, corresponding to less significant 6 bytes, are permanently allocated to solenoid valve positions, regardless how many they physically are and how many valves are installed. The remaining 16 outputs can be used to handle optional output modules. Bytes allocation to optional modules is done automatically. Two part-numbers have been provided to tailor configuration on your needs. 5830.64.48IK part number is recommended in case several solenoid valves must be handled, whilst ensuring room for future expansions. 5830.64.32IK part number is recommended in case increased flexibility is needed for digital outputs. Ordering code 5830.64.32IK 5830.64.48IK Scheme / Overall dimensions and I/O layout CLASS B connector 4 1 3 2 M12A 5P MALE 5 PIN SIGNAL 1 L+ 2 P24 (+24 VDC) 3 L- 4 C/Q 5 N24 (GND) 42 90 28 Technical characteristics

RkJQdWJsaXNoZXIy NzYzOTY1