NW97-EN

Modular FRL Series Airplus Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice AIR TREATMENT 62 Order codes Version N : Technopolymer body and metal inserts (not available for size 4) T : Technopolymer body and thread (not available for size 4) P : Aluminum body (not available for size 1) L : Aluminium body, low temperature (not available for solenoid version) Size and connections 1A : Size 1 - G1/8” only for N version 1B : Size 1 - G1/4” only for T - N versions 1C : Size 1 - 1/4” NPT only for N version 2A : Size 2 - G1/4” only for N version 2B : Size 2 - G3/8” for all versions 2C : Size 2 - 3/8” NPT only for N version 3A : Size 3 - G3/8” only for N version 3B : Size 3 - G1/2” for all versions 3C : Size 3 - 1/2” NPT only for N version 4B : Size 4 - G1” only for P - L versions Operator L : Manual P : Pneumatic E : Solenoid Coil options 15 mm coil A4 : 12 VDC A5 : 24 VDC A6 : 24 VAC (50-60 Hz) A7 : 110 VAC (50-60 Hz) A8 : 230 VAC (50-60 Hz) A9 : 24 VDC (1 Watt) 22 mm coil B2 : Mechanical M2, without coil B4 : 12 VDC B5 : 24 VDC B6 : 24 VAC (50-60 Hz) B7 : 110 VAC (50-60 Hz) B8 : 230 VAC (50-60 Hz) B9 : 24 VDC (2 Watt) (Atex certification not available) 30 mm coil C5 : 24 VDC C6 : 24 VAC (50-60 Hz) C7 : 110 VAC (50-60 Hz) C8 : 230 VAC (50-60 Hz) C9 : 24 VDC (2 Watt) (Atex certification not available) Example : T173BVEA5 : Size 3 electric shut off valve G1/2”, 15 mm coil, 24 VDC T 17 3B V E A5

RkJQdWJsaXNoZXIy NzYzOTY1