Optyma-S e Optyma-Sc
Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice Multipolar connections Air distribution Solenoid valves manifold 11 Series 2200 "OPTYMA-S" PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 PIN 11 PIN 12 PIN 13 PIN 14 PIN 15 PIN 16 PIN 17 PIN 18 PIN 19 PIN 20 PIN 21 PIN 22 PIN 23 PIN 24 PIN 25 PIN 26 PIN 27 PIN 28 PIN 29 PIN 30 PIN 31 PIN 32 PIN 33 PIN 34 PIN 35 PIN 36 PIN 37 SUB-D 37 POLE MALE CONNECTOR 1 - 32 = Solenoid valves signals 33 - 35 = GND 36 - 37 = Through line PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 PIN 11 PIN 12 PIN 13 PIN 14 PIN 15 PIN 16 PIN 17 PIN 18 PIN 19 PIN 20 PIN 21 PIN 22 PIN 23 PIN 24 PIN 25 1 - 22 = Solenoid valves signals 23 - 24 = GND 25 = Through line SUB-D 25 POLE MALE CONNECTOR PIN 13 PIN 12 PIN 11 PIN 10 PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 PIN 25 PIN 24 PIN 23 PIN 22 PIN 21 PIN 20 PIN 19 PIN 18 PIN 17 PIN 16 PIN 15 PIN 14 1 - 22 = Solenoid valves signals 23 - 24 = GND 25 = Through line SUB-D 25 POLE FEMALE CONNECTOR INLET ELECTRIC CONNECTIONS OUTLET ELECTRIC CONNECTIONS (IF PRESENT) Unused electrical signals The electrical signals which have not been used in the manifold can be made available by using the end plate fitted with the 25 pole connector. The number of electric signals available depends on the type of connector mounted on the inlet plate and on the number of signals used in the manifold: 37 pole Inlet connector : N. of outputs= 32 – used signals (max 22) 25 pole Inlet connector : N. of outputs= 22 – used signals Here are some examples of possible configurations and the corresponding pin layout both on the inlet and end plate :
Made with FlippingBook
RkJQdWJsaXNoZXIy NzYzOTY1