Optyma-S e Optyma-Sc

Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice Solenoid valves manifold Series 2200 "OPTYMA-S" Air distribution 2 ► Solenoid - Spring Operational characteristic Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pressure range (bar) 2,5 ÷ 7 Temperature °C -5 ÷+50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Responce time according to ISO 12238, activation time (ms) 12 Responce time according to ISO 12238, deactivation time (ms) 20 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2244.01 V tube Ø4= 140 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2246.01 V tube Ø6= 400 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2248.01 V tube Ø8= 550 MANUAL OVER RIDE - SIDE 14 REMOVABLE IDENTIFICATION PLATES 12.3 128.6 68.5 51.2 LED (SOLENOID VALVE STATE) Orderingcode: 2241.52.00.39. V V VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN 05 = 24 VAC SHORTFUNCTIONCODE "A" 2241.52.00.39. V Weight 67 g ► Solenoid-Differenziale Operational characteristic Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pressure range (bar) 2,5 ÷ 7 Temperature °C -5 ÷+50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Responce time according to ISO 12238, activation time (ms) 20 Responce time according to ISO 12238, deactivation time (ms) 25 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2244.01 V tube Ø4= 140 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2246.01 V tube Ø6= 400 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2248.01 V tube Ø8= 550 MANUAL OVER RIDE - SIDE 14 REMOVABLE IDENTIFICATION PLATES 12.3 128.6 68.5 51.2 LED (SOLENOID VALVE STATE) Orderingcode: 2241.52.00.36. V V VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN 05 = 24 VAC SHORTFUNCTIONCODE "B" 2241.52.00.36. V Weight 67 g ► Solenoid-Solenoid Operational characteristic Fluid Filtered air. No lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pressure range (bar) 2,5 ÷ 7 Temperature °C -5 ÷+50 Flow rate at 6 bar with Δp=1 (Nl/min) 550 Responce time according to ISO 12238, activation time (ms) 10 Responce time according to ISO 12238, deactivation time (ms) 10 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2244.01 V tube Ø4= 140 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2246.01 V tube Ø6= 400 Flow rate at 6 bar with Δp=1 (Nl/min) with Base cod. 2248.01v V tube Ø8= 550 MANUAL OVER RIDE - SIDE 14 MANUAL OVER RIDE - SIDE 12 LED (SOLENOID VALVE STATE) REMOVABLE IDENTIFICATION PLATES 12.3 128.6 68.5 51.2 Orderingcode: 2241.52.00.35. V V VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN 05 = 24 VAC SHORTFUNCTIONCODE "C" 2241.52.00.35. V Weight 67 g

RkJQdWJsaXNoZXIy NzYzOTY1