Optyma-S e Optyma-Sc
Overalldimensionsand technical informationareprovidedsolely for informativepurposesandmaybemodifiedwithoutnotice Modbus/TCP Module Air distribution Solenoid valves manifold 2 3 Series 2200 "OPTYMA-S" - Serial system Modbus/TCP module is directly integrated on Optyma-S solenoid valves manifold via a 37 poles connector, normally used for multipolar cable connection. Optyma-S solenoid valves connected to node must be PNP equivalent (final 02 in ordering code). The node can be easily installed also on solenoid valves manifold already mounted on equipment. Module can manage up to 32 solenoid valves, and, in the same time, a max number of 4 Input modules 5222.08S. The Modbus/TCP module, regardless the number of Input module connected, reports to have connected 8 Input modules. Regardless of the number of Input modules connected, themanagable solenoid valves are 32. Node power supply ismade by aM12 4Pmale circular connector. The separation between node 24 VDC Power supply and outputs 24 VDC allows to switch off the outputsmaintaning powered the node and inputs, if present. Connection to Bus Modbus/TCP is possible via 2 M12 4P type D female circular connectors. These two connectors lead the signal to two different communication ports, so they are not connected in parallel. The node address is assigned during configuration. General: Ordering code 5722.32S.MT Scheme / Overall dimensions and I/O layout : M12 4P FEMALE M12 4P FEMALE NETWORK connectors M12 4P MALE POWER SUPPLY connector PIN 1 2 3 4 DESCRIPTION +24 VDC (NODE & INPUTS) +24 VDC (OUTPUTS) NC GND Technical characteristics DESCRIPTION Ethernet Transmit High Ethernet Receive High Ethernet Transmit Low Ethernet Receive Low 1 2 3 4 TX+ RX+ TX- RX- PIN SIGNAL 1 2 4 3 1 2 4 3 2 1 3 4 2 M12 4P female connectors Type D (IEC 61076-2-101) Power supply Outputs Network Model Specifications Case Power supply connection Power supply voltage Node consumption ( ) without inputs Power supply diagnosis PNP equivalent outputs Maximum current for each output Maximum output number Max output simultaneously actuated Network connectors Baud rate Addresses, possible numbers Max nodes in net Maximum distance between 2 nodes Bus diagnosis Configuration file IP protection grade Temperature range 5722.32S.MT MODBUS Application Protocol Specification V1.1a, June 4, 2004 Reinforced technopolymer M12 4P male connector (IEC 60947-5-2) +24 VDC +/- 10% 400 mA Green LED PWR / Green LED OUT +24 VDC +/- 10% 100 mA 32 32 100 Mbit/s 248 248 100 m 1 green and 1 red LED for status + 2 LEDs for link & activity Modbus/TCP nodes don’t require configuration file IP65 when assembled From 0° to +50° C 99 63 52 MAX 32 OUT
Made with FlippingBook
RkJQdWJsaXNoZXIy NzYzOTY1