N095-EN_NAMUR

14 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice. 5/2, G1/4" Valves and Solenoid valves Series 515 "NAMUR" AIR DISTRIBUTION Valves andSolenoid515Series, "NAMUR" 5/2,G1/4" Soenoid -Differential /Sol noid-Spring Solenoid - Differential / Solenoid - Spring Ordering code m 515.52.00. v . to m MODEL =STANDARD Valve X=ATEX Valve v VERSION 36=Solenoid - Differential 39=Solenoid - Spring t VOLTAGE B04=12 VDC B05=24 VDC B09=24 VDC (2W) B56=24V (50-60 Hz) B57=110V (50-60 Hz) B58=230 V (50-60 Hz) C04=12 VDC C05=24 VDC C09=24 VDC (2W) C56=24V (50-60 Hz) C57=110V (50-60 Hz) C58=230 V (50-60 Hz) F04=12 VDC F05=24 VDC F56=24V (50-60 Hz) F57=110V (50-60 Hz) F58=230 V (50-60 Hz) o TEMPERATURE OPTIONS =STANDARD Valve (-10 ÷ +50) =ATEX Valve (-20 ÷ +40) LT=Low temperature (-30 ÷ +50) “LT” Version is available only with MB and MC coils Weight g. 330 Minimum pilot pressure 2,5 bar Maximum fixing torque for fittings 9 N/m Code Example MODELL Operational characteristics Fluid Flow rate at 6 bar with ∆ p=1 (Nl/min) Max working pressure (bar) Orifice size (mm) Working ports size Temperature °C 515.52.00. V . T STANDARD Valve Filtered and lubricated air 1100 10 8 G1/4" -10 ÷ +50 515.52.00. V . T LT LT “Low Temperture” Valve -30 ÷ +50 X515.52.00. V . T ATEX Valve -20 ÷ +40

RkJQdWJsaXNoZXIy NzYzOTY1