300 raccordi in acciaio inox • stainless steeel fittings ® 110 SS TEST REPORT N. DATA DURATA (GIORNI) COMPONENTE MATERIALE OBIETTIVO DEL TEST A TRHZ1208110 06/08/2012 6 GUARNIZIONE DI TENUTA VITON FPM FLUORORUBBER (FKM) CONFORMITA’ ALLE SPECIFICHE FDA PER DETERMINARE IL GRADO DI ESTRAZIONE DI CLOROFORMIO SOLUBILE (ppm) NELLE GUARNIZIONI DI TENUTA PER CHIUSURA DI CONTENITORI ALIMENTARI B TRHZ1208111 06/08/2012 6 RACCORDO AD L MOD. SSV ACCIAO INOSSIDABILE SUS316L DETERMINAZIONE DEL CONTENUTO TOTALE DI CROMO C TRHZ1208112 06/08/2012 6 RACCORDO DIRITTO MOD. SSC-G ACCIAO INOSSIDABILE SUS316L DETERMINAZIONE DEL CONTENUTO TOTALE DI CROMO METODO DEL TEST (ref. FDA 21 CFR 177.1210) RISULTATO CONCLUSIONI A IMMERSIONE PER 2 ORE IN ACQUA DISTILLATA A212°F VALORE RILEVATO 13,0 VALORE LIMITE 50,0 IL RISULTATO DEL TEST SUI CAMPIONI PRESENTATI SONO CONFORMI ALLE SPECIFICHE FDA PER DETERMINARE LA QUANTITA’ DI ESTRATTIVI DI CLOROFORMIO SOLUBILE AMMESSI IMMERSIONE PER 2 ORE IN ALCOHOL 8% A 212°F VALORE RILEVATO 7,0 VALORE LIMITE 50,0 IMMERSIONE PER 2 ORE IN EPTANO NORMALE (N-EPTANO) A 150 °F VALORE RILEVATO 11,5 VALORE LIMITE 50,0 B ANALISI VOLUMETRICA (TITOLAZIONE) VALORE RILEVATO 16,38% VALORE RICHIESTO >=10,5% IL RISULTATO DEL TEST SUL CAMPIONE PRESENTATO DETERMINA CHE ESSO E’ IDONEO AL CONTATTO CON GLI ALIMENTI C ANALISI VOLUMETRICA (TITOLAZIONE) VALORE RILEVATO 17,18% VALORE RICHIESTO >=10,5% IL RISULTATO DEL TEST SUL CAMPIONE PRESENTATO DETERMINA CHE ESSO E’ IDONEO AL CONTATTO CON GLI ALIMENTI Test results to FDA specifications compatibility, made by on behalf of the manufacturer Esito dei test di compatibilità alle specifiche FDA effettuati da per conto del produttore TEST REPORT N. DATE PERIOD (DAYS) ITEM MAIN MATERIAL TEST PURPOSE A TRHZ1208110 06/08/2012 6 SEAL RING FPM FLUORORUBBER VITON (FKM) THE COMPLIANCE WITH THE FOOD AND DRUG ADMINISTRATION REGULATIONS FOR DETERMINING THE AMOUNT OF CHLOROFORM-SOLUBLE EXTRACTIVES (ppm) FROM CLOSURES WITH SEALING GASKETS FOR FOOD CONTAINERS B TRHZ1208111 06/08/2012 6 ELBOW FITTING MOD. SSV STAINLESS STEEL SUS316L TO DETERMINE TOTAL CHROMIUM CONTENT IN THE SUBMITTED SAMPLE C TRHZ1208112 06/08/2012 6 STRAIGHT FITTING MOD. SSC-G STAINLESS STEEL SUS316L TO DETERMINE TOTAL CHROMIUM CONTENT IN THE SUBMITTED SAMPLE TEST METHOD (ref. FDA 21 CFR 177.1210) TEST RESULT CONCLUSION A IMMERSION FOR 2 HOURS IN DISTILLED WATER AT 212 ° F DETECTED VALUE 13,0 MAX PERMISSIBLE 50,0 WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE COMPLY WITH THE FDA SPECIFICATIONS FOR DETERMINING THE AMOUNT OF CHLOROFORM-SOLUBLE EXTRACTIVES FOR CLOSURES (CLOS) IMMERSION FOR 2 HOURS IN ALCOHOL 8% AT 212°F DETECTED VALUE 7,0 MAX PERMISSIBLE 50,0 IMMERSION FOR 2 HOURS IN n-HEPTANE AT 150°F DETECTED VALUE 11,5 MAX PERMISSIBLE 50,0 B TITRATION METHOD DETECTED VALUE 16,38% REQUIREMENT >=10,5% WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE IS SUITABLE FOR CONTACT WITH FOOD C TITRATION METHOD DETECTED VALUE 17,18% REQUIREMENT >=10,5% WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE IS SUITABLE FOR CONTACT WITH FOOD dimensioni di ingombro e informazioni tecniche sono fornite a puro titolo informativo e possono essere soggette a modifica senza preavviso
RkJQdWJsaXNoZXIy NzYzOTY1